Shielded LV Power Cable, 0.6/1kV

0.6/1kV cable with a copper tape or braided screen and drain wire, for variable speed drive outputs and feeders in electrically noisy plants.

Voltage0.6/1 kV
ScreenCu tape / braid
Size1.5 – 300 mm²
DrainTinned Cu
StandardIEC 60502-1
Description

Construction and behaviour

A shielded power cable controls the electric field around the conductors. On variable speed drive outputs the PWM waveform produces high-frequency currents that travel on the cable surface, radiate into nearby signal cables and can interfere with encoders, sensors and communications.

A copper tape or braided screen with a drain wire provides a low-impedance return path for those currents. The screen must be earthed at both ends for the high-frequency component to circulate, and the gland or clamp must bond the screen around its full circumference — a pigtail connection defeats most of the benefit.

Copper tape gives high coverage at lower cost and is the usual choice for fixed feeders. Braided copper is more flexible and better for installations that need repeated bending or where mechanical robustness of the screen matters.

Shielded cable is not a substitute for separation. Keep power and signal routes apart, cross at right angles where they must meet, and bond the screen to the same earth reference as the drive. Screening and routing work together.

Technical parameters

Specification table

StandardIEC 60502-1, IEC 60228
Rated voltage0.6/1 kV (U0/U)
ConductorClass 1 or Class 2 copper
Cross-section1.5 – 300 mm²
InsulationXLPE (90 °C) or PVC (70 °C)
ScreenCopper tape (overlapping) or braided copper, coverage on request
Drain wireTinned copper, 0.5 – 6 mm² depending on size
SheathPVC ST2, PE or LSZH
Bending radius12 × overall diameter
TerminationFull-circumference screen bond at both ends
PackingDrum, project lengths
Standards: manufactured and tested to IEC 60502-1 and IEC 60228. Type test reports and routine test results are issued with the batch documents.
Options

Available constructions

ConstructionTypical use
Cu / XLPE / Cu tape / PVCVFD output and feeder cable for fixed installation.
Cu / XLPE / braid / PVCHigher flexibility and mechanical screen robustness.
Cu / XLPE / Cu tape / LSZHScreened and low smoke for tunnels and public buildings.
Screened + STAScreened cable with steel tape armour for buried routes.
Applications

Where it is used

  • VFD outputs — Motor cables between drive and motor where PWM noise is present.
  • Automation plants — Feeders running alongside encoder, sensor and network cabling.
  • Data & telecom rooms — Power feeds into areas with sensitive equipment.
  • Substations — Low voltage circuits in electrically noisy yards.
Packing & delivery

How it ships

  • Drums marked with length, screen type and gross weight.
  • Screen coverage and drain wire size stated on the drum label and test report.
  • Glands with full-circumference bonding can be quoted with the cable.
  • Drum schedule issued before shipment.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Technical FAQ

Questions buyers ask about this cable

Should the screen be earthed at one end or both?
For drive output cables and EMI control, bond at both ends. Single-end bonding is used in specific low-frequency analogue situations and does not control high-frequency noise.
Does a screen reduce the cable current rating?
Slightly. The screen adds thermal resistance and, in some arrangements, circulating currents. Confirm derating if the cable is fully loaded or grouped with others.
Can I use shielded cable for the motor and unshielded for the supply?
Yes, and it is common practice: screen the drive-to-motor cable, which carries the PWM waveform, and use a standard cable on the supply side.
What coverage do you offer?
Copper tape is normally specified as overlapping tape giving full coverage; braided screens are quoted by coverage percentage, typically 85 % or higher. State the requirement if the project specifies a value.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Related products

Often specified with this cable

Related constructions from the same or a neighbouring family.

All products

Request a quotation for Shielded LV Power Cable

Share the application, voltage, core count, conductor size, screen or armour, sheath and delivery destination. Our engineering team replies within one business day.

This field is required.
This field is required.
This field is required.