In a fire, ordinary PVC cable releases dense smoke and hydrogen chloride. That is a problem in tunnels, metro stations, hospitals, shopping centres and any confined plant area where people have to evacuate and equipment has to survive. LSZH cable replaces the PVC with a halogen-free compound that produces limited smoke and non-corrosive combustion gases.

0.6/1 kVLSZH sheath1.5–400 mm²IEC 61034IEC 60754Cat. C flame
Request a Quotation
Technical parameters

Construction and ratings

Rated voltage0.6/1 kV (U0/U)
Cores1 – 5 cores, 3+1, 4+1
Cross-section1.5 – 400 mm²
InsulationXLPE, or LSZH compound for smaller sections
SheathLSZH compound, halogen free
Smoke densityIEC 61034-2, light transmittance ≥ 60 %
Halogen gasIEC 60754-1 / -2, HCl < 0.5 %, pH ≥ 4.3, conductivity ≤ 10 µS/mm
Flame propagationIEC 60332-1-2 and IEC 60332-3-24 (Cat. C)
Values are for the standard construction. Current ratings depend on installation method, ambient temperature and grouping — confirm against IEC 60364-5-52 before finalising the section.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Performance

What the construction gives you

  • Low smoke emission keeps escape routes visible for longer and reduces damage to switchgear and electronics.
  • Halogen-free combustion gases avoid the hydrochloric acid that attacks steel structures and circuit boards.
  • Flame propagation is tested on bunched cable to IEC 60332-3-24 Cat. C, the usual requirement for tray and ladder installations.
  • Mechanical properties are slightly lower than PVC, so support spacing and bending radius should follow the datasheet rather than PVC practice.
  • CPR classification (BS EN 50575) can be provided for European projects on request.
Where it is used

Applications

Metro & tunnels

Escape routes, tunnel lighting, ventilation and signalling power feeders.

Public buildings

Airports, hospitals, shopping centres, cinemas and high-rise risers.

Data & control rooms

Areas where smoke and corrosive gas would destroy sensitive equipment.

Confined plant areas

Basements, cable cellars and enclosed process rooms with limited egress.

Technical FAQ

Frequently asked questions

Is LSZH the same as LSOH or LSF?
They describe the same idea. LSZH (low smoke zero halogen), LSOH (low smoke zero halogen) and LSF (low smoke and fume) are all used in the market. Ask for the test values, not the label: smoke density to IEC 61034 and halogen content to IEC 60754.
Can LSZH cable be used outdoors?
Standard LSZH compounds are formulated for indoor use. For outdoor or wet routes specify a black UV-stabilised LSZH grade, or use PE sheathing where halogen content is not the governing requirement.
Does LSZH cable cost more?
Yes, typically 20–40 % more than an equivalent PVC cable because of the compound cost. The premium is normally accepted only where the fire strategy or insurer requires it.
Are your LSZH cables CPR classified?
We can supply cables tested to BS EN 50575 with a declared Euroclass for European projects. State the required class (for example Cca-s1,d1,a1) and the declaration will be included in the test documentation.