Fire Resistant LV Cables

Fire Resistant Power Cable, 0.6/1kV

0.6/1kV cable with a mica glass tape barrier over each conductor, XLPE insulation and an LSZH sheath, for circuits that must keep working during a fire.

Voltage0.6/1 kV
BarrierMica tape
Size1.5 – 300 mm²
TestBS 6387 CWZ
SheathLSZH
Description

Construction and behaviour

Fire resistant cable is built around one functional layer: the mica glass tape wrapped directly over the conductor. When the insulation burns away, the mica sinters into a ceramic shell that still separates the conductor from earth, so the circuit keeps conducting while the fire continues.

That is why the position of the barrier matters. A cable with a fire retardant sheath but no mica layer will resist flame spread and still lose circuit integrity within minutes. When a specification asks for fire resistance, the question to ask is which test and which barrier.

The common tests are IEC 60331-21 at 750 °C for 90 minutes, and BS 6387 categories CWZ, which add water spray (W) and mechanical shock (Z) at 950 °C. Life-safety systems in tunnels, high-rise buildings and hospitals are normally specified to CWZ.

We build the cable with XLPE over the mica barrier and an LSZH sheath as standard, so the same cable addresses smoke density and corrosive gas as well as circuit integrity. Test reports are supplied with the batch documents.

Technical parameters

Specification table

StandardIEC 60502-1, IEC 60331-21, BS 6387 CWZ
Rated voltage0.6/1 kV (U0/U)
ConductorClass 1 or Class 2 copper
Cross-section1.5 – 300 mm²
Fire barrierMica glass tape, lapped over conductor
InsulationXLPE
SheathLSZH (standard) or PVC
Fire resistanceIEC 60331-21 750 °C / 90 min; BS 6387 C, W, Z at 950 °C
Flame propagationIEC 60332-3-24 Cat. C
Smoke & halogenIEC 61034, IEC 60754
PackingDrum, project lengths
Standards: manufactured and tested to IEC 60502-1 and IEC 60228. Type test reports and routine test results are issued with the batch documents.
Options

Available constructions

ConstructionTypical use
Cu / mica / XLPE / LSZHStandard fire survival cable for indoor life-safety circuits.
Cu / mica / XLPE / LSZH + STAFire resistant with steel tape armour for buried or exposed sections.
Cu / mica / XLPE / PVCFire resistance where LSZH is not required.
Screened FRFire resistant with copper screen for control and alarm circuits.
Applications

Where it is used

  • Emergency lighting — Exit signs, escape route lighting and standby circuits.
  • Fire pumps — Pump feeders and control circuits required to run during a fire.
  • Smoke control — Pressurisation fans, dampers and extract systems.
  • Life safety systems — Fire alarm feeders, lift homing and public address.
Packing & delivery

How it ships

  • Drums sealed against moisture for sea freight.
  • Batch test reports for IEC 60331 / BS 6387 included with documents.
  • Fire-rated glands and supports can be quoted with the cable.
  • Drum schedule issued before shipment.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Technical FAQ

Questions buyers ask about this cable

What is the difference between fire resistant and flame retardant?
Flame retardant cable resists ignition and limits flame spread. Fire resistant cable maintains circuit integrity during a fire because of the mica barrier. A life-safety circuit needs the second property, and preferably both.
Which test should be specified?
IEC 60331-21 is the international baseline. BS 6387 CWZ is stricter and is usual for tunnels, high-rise and hospital projects. State the required duration and temperature in the specification.
Does the mica barrier affect current rating?
The barrier adds a small thermal resistance, but the effect is minor compared with installation conditions. The cable is rated as an XLPE 90 °C construction; confirm derating for grouping and ambient temperature.
Can it be terminated with standard glands?
Use fire-rated glands and follow the strip length so the mica tape is not damaged. Termination quality is a common cause of circuit-integrity failure in service.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Related products

Often specified with this cable

Related constructions from the same or a neighbouring family.

All products

Request a quotation for Fire Resistant LV Power Cable

Share the application, voltage, core count, conductor size, screen or armour, sheath and delivery destination. Our engineering team replies within one business day.

This field is required.
This field is required.
This field is required.