Skip to content
IEC 60502-1 · IEC 60228  ·  LV Power, Armoured, LSZH & Fire-Resistant Cable Manufacturer
ZMS Cable logo
Home  /  Products  /  LV Power Cables (0.6/1kV)  /  0.6/1kV PVC/XLPE Insulated LV Power Cable
LV Power Cables (0.6/1kV)

0.6/1kV Power Cable, PVC or XLPE Insulated

Copper or aluminium conductor, PVC (70 °C) or XLPE (90 °C) insulation, 1 to 5 cores from 1.5 to 630 mm², sheathed in PVC, PE or LSZH to IEC 60502-1.

Voltage0.6/1 kV
Cores1 – 5
Size1.5 – 630 mm²
InsulationPVC / XLPE
StandardIEC 60502-1
Description

Construction and behaviour

This is the workhorse cable of low voltage distribution. It takes power from a panel or distribution board to machines, sub-boards, lighting circuits and building services, and it is the cable most often quoted when a project simply says “0.6/1kV power cable”.

The construction is straightforward: Class 1 solid or Class 2 stranded conductor, an extruded insulation layer, cores laid up with fillers, and an extruded outer sheath. What changes between projects is the insulation compound, the sheath compound and the core identification — and those three decisions are what determine service life and compliance.

Copper is the default conductor for industrial work because of its conductivity and termination behaviour. Aluminium is specified where weight and cost dominate on larger sections; it needs bimetallic lugs and a slightly larger cross-section for the same current.

For fixed routes in dry indoor areas, PVC insulation at 70 °C is sufficient and economical. Where the cable is fully loaded, exposed to sunlight, or installed in a hot plant room, XLPE at 90 °C allows a smaller conductor for the same load and gives better moisture resistance.

Technical parameters

Specification table

StandardIEC 60502-1, IEC 60228, IEC 60332-1-2
Rated voltage0.6/1 kV (U0/U)
ConductorClass 1 solid or Class 2 stranded copper; aluminium on request
Cross-section1.5 – 630 mm² (copper), 16 – 400 mm² (aluminium)
InsulationPVC type PVC/C (70 °C) or XLPE (90 °C)
Core arrangement1, 2, 3, 3+1, 4, 4+1, 5 cores; shaped conductor on larger multicore
Core identificationColour to HD 308, or numbered cores above 5 cores
SheathPVC ST1/ST2, PE or LSZH; black standard, other colours on request
Temperature rangePVC: −5 °C to +70 °C; XLPE: −15 °C to +90 °C
Bending radius12 × overall diameter (fixed installation)
Test voltage3.5 kV AC / 5 min between conductors and sheath
PackingSteel or wooden drum, 500 m / 1000 m, or project lengths
Standards: manufactured and tested to IEC 60502-1 and IEC 60228. Type test reports and routine test results are issued with the batch documents.
Options

Available constructions

ConstructionTypical use
Cu / PVC / PVCStandard indoor cable, 70 °C, lowest cost for dry routes.
Cu / XLPE / PVCHigher current rating and 90 °C conductor for loaded circuits.
Cu / XLPE / PEMoisture-resistant sheath for ducts, wet areas and light burial.
Cu / XLPE / LSZHLow smoke halogen free where escape routes or equipment protection matter.
Al / XLPE / PVCCost and weight saving on larger feeders; bimetallic lugs required.
Applications

Where it is used

  • Machine and motor feeds — Final circuits inside workshops, from sub-board to machine isolator.
  • Sub-distribution — Panel-to-panel feeders in factories, warehouses and commercial buildings.
  • Lighting and small power — Fixed lighting circuits, socket final circuits and HVAC connections.
  • Auxiliary supply — Low voltage auxiliary circuits in plants and renewable energy stations.
Packing & delivery

How it ships

  • Drums are marked with cable description, length, drum number and gross weight.
  • Length marking every metre on request for long pulls and cable schedules.
  • Drum schedule issued before shipment so the site team can match drums to pulls.
  • Export packing with timber treatment certificate where the destination requires it.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Technical FAQ

Questions buyers ask about this cable

What is the current rating of a 4 × 25 mm² cable?
It depends on installation method, ambient temperature, grouping and soil conditions. For a copper XLPE cable in free air at 30 °C, 4 × 25 mm² is typically around 96–110 A; buried or grouped it drops. Send the installation method and we will confirm against IEC 60364-5-52.
Can I get a 3+1 core configuration?
Yes. 3+1 and 4+1 are standard configurations and are usually the most economical way to provide a reduced neutral or a separate earth core.
Do you provide test certificates?
Every batch ships with routine test results (conductor resistance, voltage test, insulation resistance) and a certificate of conformity. Type test reports are available for project documentation.
What is the lead time for a 20 km order?
Standard constructions are typically 15–20 working days after drawing and colour approval, plus sea freight. Confirmed dates are given with the quotation.

Request datasheet & price

Send the project specification and we will confirm construction, standard and delivery schedule. Samples for approval can be arranged.

Get a Quote WhatsApp Us
Response< 24 h
MOQOn request
Related products

Often specified with this cable

Related constructions from the same or a neighbouring family.

All products
Aluminium conductor low voltage power cable with XLPE insulation
LV Power Cables (0.6/1kV)

Aluminum Conductor LV Cable

0.6/1kV aluminium conductor cable for long feeders where weight and cost matter: XLPE insulation, 16 to 400 mm², PVC or PE sheath.

0.6/1 kVAluminium16 – 400 mm²
View product →
Shielded low voltage power cable with copper tape screen
LV Power Cables (0.6/1kV)

Shielded LV Power Cable

0.6/1kV cable with copper tape or wire screen and drain wire for VFD outputs, EMI-heavy plants and sensitive equipment feeds.

0.6/1 kVCu tape / braid1.5 – 300 mm²
View product →
Steel tape armoured low voltage power cable with XLPE insulation
Armoured LV Cables

Steel Tape Armoured LV Cable

STA and DSTA 0.6/1kV cable for direct burial and exposed routes: XLPE insulation, PVC bedding, galvanised steel tape, PE or PVC outer sheath.

0.6/1 kVSTA / DSTA4 – 400 mm²
View product →

Request a quotation for 0.6/1kV PVC/XLPE Insulated LV Power Cable

Share the application, voltage, core count, conductor size, screen or armour, sheath and delivery destination. Our engineering team replies within one business day.

This field is required.
This field is required.
This field is required.